200+
EGA installations
MAN, Caterpillar
OEM trained specialists
24/7
EGA support
Experienced
team – 15+ years

⚡ emergency generator automation (ega)

Auto-start · Load Transfer · Blackout · PMS

  • Emergency Generator Auto-start Systemsblackout detection, automatic start
  • ✓ Automatic Load Transfer – ESB (Emergency Switchboard) transfer
  • ✓ Blackout Recovery & Sequencing – priority start, load shedding
  • ✓ Integration with Power Management System (PMS)
  • ✓ Remote Monitoring & Alarms – bridge/ECR panels
  • ✓ Emergency Generator Controller Panels – Selco, Comap, Deif, Woodward
  • ✓ Battery Charger & Starting System Monitoring
  • ✓ Fuel Valve & Governor Control for Emergency Genset
  • ✓ Emergency Stop & Safety Interlocks
  • ✓ Class Compliance – SOLAS, ABS, DNV, LR, BV
  • ✓ Weekly / Monthly Auto-test Functions
  • ✓ Integration with IAS/AMS

Experienced with MAN, Wärtsilä, Caterpillar, MTU, Yanmar, ABC, Daihatsu, Scania, Volvo Penta, Cummins, Kohler – our team delivers.

🎛️ emergency generator controllers

Selco · Comap · Deif · Woodward · Deep Sea

Emergency Genset Controller Makes

  • Selco – Genesis, S-series, NEMA4 marine controllers
  • Comap – InteliMains, InteliGen, InteliSys NTC
  • Deif – AGC 100, AGC 150, AGC 200, AGC 4xx
  • Woodward – easYgen-1000, 2000, 3000, 3500
  • Deep Sea Electronics – DSE 3110, 4510, 7310, 8610
  • ABB – Genset controllers, SACE
  • Norcontrol – AutoChief, DGS 8800e emergency integration
  • Siemens – PLC-based emergency control

Automation Functions

  • ✓ Blackout start – < 45 seconds (SOLAS)
  • ✓ Automatic voltage & frequency regulation
  • ✓ Load shedding & priority management
  • ✓ Synchronization with main switchboard
  • ✓ Remote start/stop from bridge/ECR
  • ✓ Emergency stop & safety interlocks
  • ✓ Battery charger monitoring
  • ✓ Weekly auto-test with load

🔧 emergency genset models

We Support These Emergency Generator Engines

MAN / Wärtsilä / Caterpillar

  • MAN – 7L21/31, 9L23/30H, 10L23/30H, 12V28/33D
  • Wärtsilä – 4L20, 6L20, 6L26, 8L26 (auxiliary gensets)
  • Caterpillar – C4.4, C6.6, C7.1, C9.3, C18, C32, 3412, 3508
  • MAK – M20, M25, M32 (emergency genset versions)
  • MTU – 8V396, 12V396, 8V2000, 12V2000, 16V4000

Yanmar / ABC / Daihatsu / Others

  • Yanmar – 6EY17, 6EY22, 8EY22, 12EY22, 6HY, 8HY
  • ABC – 6DZC, 8DZC, 12DZC (1000-3000kW gensets)
  • Daihatsu – 6DK-20, 8DC-32, 12DC-32
  • Scania – DI09, DI13, DI16 (marine genset)
  • Volvo Penta – TAD1341, TAD1342, TAD1641, TAD1642
  • Cummins – QSK19, QSK38, QSK60, KTA19 (genset)
  • Kohler – 20-1500kW marine emergency gensets
  • Mitsubishi – S6, S8, S12 series
  • Niigata – 6L, 8L series

⚡ blackout recovery & load transfer

Auto-start · ESB Transfer · Sequencing

Blackout Recovery Sequence

  • ✓ Blackout detection (under-voltage, under-frequency)
  • ✓ Emergency genset start command (battery/air start)
  • ✓ Genset reaching rated speed & voltage
  • ✓ ESB (Emergency Switchboard) auto-close
  • ✓ Priority load connection (navigation, comms, fire)
  • ✓ Sequential load adding (pumps, steering, etc.)
  • ✓ Blackout recovery time < 45 seconds SOLAS

Load Transfer Components

  • ✓ Automatic Transfer Switches (ATS) – ABB, Schneider, Siemens
  • ✓ Emergency Switchboard PLC – Siemens, Rockwell, Mitsubishi
  • ✓ Motorized Breakers & Contactors
  • ✓ Under-voltage Release & Shunt Trip
  • ✓ Bus-tie Breaker Control
  • ✓ Load Shedding Relays – Woodward, Deif, Comap
  • ✓ Remote Annunciation – bridge/ECR

🔌 pms & ias integration

Power Management · Integrated Automation

PMS Integration (Power Management)

  • ✓ Emergency genset integration with main PMS
  • ✓ Load-dependent start/stop of emergency genset
  • ✓ Peak shaving & load shedding coordination
  • ✓ Blackout prevention & fast load reduction
  • ✓ Communication protocols – Modbus, Profibus, CANbus, Ethernet/IP
  • Kongsberg K-Chief, Norcontrol, Valmet, ABB, Siemens PMS

IAS / AMS Integration

  • ✓ Integration with Kongsberg K-Chief 700, Norcontrol, Lyngsø, Valmet
  • ✓ Remote monitoring – start/stop, alarms, status
  • ✓ Data logging & trend analysis
  • ✓ Alarm management & history
  • ✓ Fuel level, battery voltage, running hours
  • ✓ Automatic report generation

🔧 ega retrofit & upgrade

Modernization · Legacy Controllers · Diagnostics

  • Legacy emergency controller upgrade – replacing obsolete units
  • PLC-based emergency automation – Siemens, Rockwell, Mitsubishi
  • HMI retrofit – touchscreen, SCADA interface
  • Battery charger & starting system upgrade
  • Blackout recovery logic reprogramming
  • Load shedding & priority control retrofit
  • Remote monitoring & alarm integration
  • Class compliance upgrades – SOLAS, IACS
  • On-site troubleshooting & diagnostics
  • Spare parts supply – all major EGA makes

🌍 ega service coverage

Vessels We Serve with EGA Expertise

Vessel Types

  • ✓ Tankers (VLCC, Aframax, Product)
  • ✓ Bulk Carriers (Capesize, Panamax)
  • ✓ Container Vessels (Post-Panamax)
  • ✓ LNG / LPG Carriers
  • ✓ Offshore Vessels (PSV, AHTS, OSCV)
  • ✓ Drilling Rigs (Jack-up, Semi-sub)
  • ✓ FPSO / FLNG / FSRU
  • ✓ Ro-Ro / PCTC / Car Carriers
  • ✓ Cruise Ships / Ferries
  • ✓ Naval Vessels
  • ✓ Mega Yachts

Global Service Locations

  • ✓ UAE – Dubai, Abu Dhabi, Fujairah
  • ✓ India – Mumbai, Kochi, Chennai, Kandla
  • ✓ Singapore – Jurong, Tuas
  • ✓ Middle East – Qatar, Saudi, Kuwait
  • ✓ Europe – Rotterdam, Hamburg, Piraeus
  • ✓ Asia – South Korea, China, Japan
  • ✓ Worldwide – all major ports and shipyards

⚡ 24/7 emergency generator automation support

Need Emergency Generator Automation
service or retrofit?

Our EGA engineers provide complete installation, troubleshooting, retrofit, and repair services for all emergency generator automation systems – Auto-start, Load Transfer, Blackout Recovery, PMS Integration. Available 24/7 worldwide.

Email: service@seanav.org | Website: www.seanav.org