950+
shutdown systems projects
20+
years experienced team
OEM
trained specialists
24/7
emergency response

🛑 emergency shutdown (esd)

Main Engine · Auxiliary · Generator ESD

  • Main Engine Emergency Shutdown Systems
  • Auxiliary Engine ESD Systems
  • Generator Engine Shutdown Systems
  • Emergency Generator Shutdown
  • Remote Shutdown Stations – Bridge, ECR, Local
  • ESD Pushbuttons & Pull Cables
  • Fuel Shutoff Valves – Manual & Pneumatic
  • Air Shutoff Valves – Starting Air & Scavenge Air
  • MAN B&W ESD Systems – MC, ME, ME-C, ME-B, G-type
  • Wärtsilä ESD Systems – RT-flex, X-series, RTA, 20-50DF
  • Sulzer RTA ESD Systems
  • MAK / Caterpillar ESD Systems – M20, M25, M32, M43, 3500, 3600

⚡ overspeed trip systems

Overspeed Protection · Trip Devices · Calibration

Overspeed Protection Systems

  • Mechanical Overspeed Trip Devices – Woodward, Heinzmann, Regulateurs Europa
  • Electronic Overspeed Protection – Woodward ProTech, 2301, TG series
  • Overspeed Trip Valves – UG, PG, PSG series
  • Speed Switches & Relays – Ifm, Pepperl+Fuchs, Turck, Banner
  • Magnetic Pickup Sensors – Speed sensing
  • Proximity Switches – Inductive, Hall-effect
  • Overspeed Testing & Calibration – Under load & no load

Manufacturer-Specific Systems

  • Woodward ProTech 203, 210, 230 Overspeed
  • Heinzmann Electronic Overspeed Governors
  • Regulateurs Europa Overspeed Trip Units
  • MAN B&W Overspeed Systems – ME engine protection
  • Wärtsilä Overspeed Trip – UNIC / WECS systems
  • Caterpillar ADEM Overspeed Protection
  • MTU Overspeed – Series 4000, 8000
  • Yanmar / Daihatsu Overspeed Systems

🐢 automatic slowdown systems

Engine Slowdown · Load Reduction · Derating

  • Automatic Engine Slowdown Systems
  • Load Reduction & Derating Systems
  • High Temperature Slowdown – Bearing, Cylinder, Exhaust
  • High Vibration Slowdown
  • Low Oil Pressure Slowdown
  • High Cooling Water Temp Slowdown
  • Oil Mist Detection Slowdown – Pre-alarm before shutdown
  • MAN B&W Slowdown Systems – ME engine protection logic
  • Wärtsilä Slowdown – UNIC, WECS, CoCoS
  • Sulzer RTA Slowdown Systems
  • MAK / Caterpillar Slowdown Logic
  • Programmable Slowdown Parameters – Custom settings

🔒 safety interlock systems

Startup Interlocks · Operational Safety · Permissives

Startup & Operational Interlocks

  • Starting Air Interlock Systems
  • Turning Gear Interlock – Prevent start with turning gear engaged
  • Lube Oil Pressure Interlock – Pre-start & running
  • Cooling Water Flow Interlock
  • Fuel Valve Interlock – Fuel rack position
  • Camshaft Position Interlock
  • Overspeed Test Interlock – Safe testing mode

Manufacturer Interlock Systems

  • MAN B&W Interlock Systems – MC, ME engine safety
  • Wärtsilä Safety Interlocks – UNIC safety logic
  • Sulzer RTA Interlock Systems
  • MAK / Caterpillar Startup Permissives
  • MTU Safety Interlocks – MCS, ECU systems
  • PLC-Based Interlock Logic – Siemens, Mitsubishi, ABB

🔧 shutdown components & actuators

Fuel Valves · Air Valves · Solenoids · Actuators

Shutdown Valves & Actuators

  • Fuel Shutoff Valves – Manual, Pneumatic, Hydraulic
  • Air Shutoff Valves – Starting air, Scavenge air
  • Solenoid Valves for Shutdown – ASCO, Norgren, Burkert, Parker
  • Pneumatic Actuators – For valve operation
  • Hydraulic Actuators – For fuel rack control
  • Emergency Stop Pull Cables & Switches
  • MAN B&W Shutdown Valves – Fuel valve, air valve
  • Wärtsilä Shutdown Actuators – UNIC system

Sensors & Switches

  • Pressure Switches – Lube oil, fuel, air
  • Temperature Switches – Bearing, coolant, exhaust
  • Level Switches – Oil sump, cooling water
  • Speed Sensors – Magnetic, proximity, Hall-effect
  • Position Sensors – Fuel rack, valve position
  • Emergency Stop Pushbuttons – IP66, marine grade
  • Safety Relays & Logic Modules – Pilz, Ifm, Siemens

📟 shutdown control panels

ESD Panels · Alarm Annunciators · HMI

Control & Monitoring Panels

  • Engine Shutdown Control Panels
  • ESD Annunciator Panels – LED/LCD display
  • Alarm & Shutdown Indication Units
  • Local Operating Panels (LOP) – With shutdown functions
  • Remote Shutdown Stations – Bridge, ECR, Accommodation
  • HMI Integration for Shutdown Monitoring
  • PLC-Based Safety Controllers – Siemens, Mitsubishi, ABB

Integration & Communication

  • Integration with IAS / AMS – Alarm monitoring
  • Modbus / Profibus Communication
  • Ethernet/IP for Shutdown Data
  • Remote Monitoring & Diagnostics
  • Event Logging & Data Recording
  • Class Survey Data Reporting – ABS, DNV, LR, BV, RINA

🔧 engine models & makes

Specific Models We Support

Two-Stroke Engines

  • MAN B&W: MC, MC-C, ME, ME-B, ME-C, ME-GI, G-type (S35 to S90)
  • Wärtsilä: RT-flex, X-series, RTA, RTA-T, RTA-C, X35 to X92
  • Sulzer: RTA, RND, RND-M, ZA40 series
  • Mitsubishi: UEC series (UEC37 to UEC85)
  • Hitachi / HH / Doosan: B&W license engines

Four-Stroke Engines

  • Wärtsilä: 20, 26, 32, 38, 46, 50DF, 34DF series
  • MAN: L21/31, L23/30, L27/38, L32/40, L48/60, 175D, 32/44CR
  • MAK: M20, M25, M32, M43, M453, M553 series
  • Caterpillar: 3400, 3500, 3600, C280 series
  • MTU: 4000, 8000, 1163 series
  • Yanmar: EY, S165, S185, 6EY series
  • Daihatsu: DK-20, DK-26, DK-28, DC-17, DC-32
  • Niigata: 28AHX, 32AHX, 40AHX series
  • ABC: DZ, DLZ, MDZ series
  • Bergen: KRM, KRG, B-series, C-series
  • Deutz / MWM / SKL / Pielstick

🔬 testing & calibration

Function Testing · Calibration · Certification

Testing Services

  • ESD Function Testing – Full simulation
  • Overspeed Trip Testing – Under load & no load
  • Slowdown System Verification
  • Safety Interlock Testing
  • Emergency Stop Circuit Verification
  • Valve Stroke Testing – Fuel shutoff, air shutoff
  • Sensor & Switch Calibration
  • Alarm & Shadow Testing – Without engine trip

Calibration & Certification

  • Overspeed Device Calibration – Woodward, Heinzmann
  • Speed Switch Calibration
  • Pressure Switch Calibration
  • Temperature Sensor Calibration – RTD, Thermocouple
  • Class Survey Support – ABS, DNV, LR, BV, RINA, NK
  • Calibration Certificates – Traceable standards
  • Shutdown System Audit & Documentation

🔄 retrofit & upgrade

Modernize Obsolete Shutdown Systems

  • Retrofit of Mechanical Overspeed to Electronic
  • Upgrade Obsolete ESD Panels – New PLC-based systems
  • Modernize Shutdown Logic – Replace relay logic with PLC
  • Integration with Modern IAS / AMS
  • Replace Obsolete Sensors & Switches – With new equivalents
  • Retrofit Remote Shutdown Stations
  • Add HMI for Shutdown Monitoring
  • Upgrade to Meet Latest Class Requirements
  • MAN B&W Shutdown Retrofit Kits
  • Wärtsilä Shutdown System Upgrades

🚢 vessels we serve

Global Shutdown System Support

Vessel Types

  • ✓ VLCC / ULCC Tankers
  • ✓ Suezmax / Aframax
  • ✓ Capesize / Panamax Bulk
  • ✓ Container Vessels (Post-Panamax)
  • ✓ LNG / LPG Carriers
  • ✓ PSV / AHTS / OSV / MPSV
  • ✓ Drilling Rigs / Semi-sub / Jack-up
  • ✓ FPSO / FSO / FLNG Units
  • ✓ Cruise Ships / Ro-Ro / Ferries
  • ✓ Naval / Coast Guard Vessels
  • ✓ Dredgers / Heavy Lift Vessels

Global Service Locations

  • ✓ UAE (Dubai, Abu Dhabi, Fujairah)
  • ✓ India (Mumbai, Kochi, Chennai, Kandla)
  • ✓ Singapore
  • ✓ Netherlands (Rotterdam, Amsterdam)
  • ✓ Norway (Stavanger, Bergen, Oslo)
  • ✓ USA (Houston, New Orleans, Seattle)
  • ✓ Brazil (Rio de Janeiro, Santos)
  • ✓ China (Shanghai, Hong Kong, Shenzhen)
  • ✓ South Korea (Busan, Ulsan)
  • ✓ Japan (Tokyo, Yokohama, Kobe)
  • ✓ Middle East / Gulf Ports
  • ✓ Worldwide Ports & Shipyards

🛑 24/7 engine shutdown emergency support

Need Engine Shutdown or Slowdown
System Service?

Our experienced shutdown system specialists (20+ years) provide complete troubleshooting, repair, calibration, and retrofitting for all marine engine shutdown and slowdown systems. Available 24/7 worldwide for emergency response.

Email: service@seanav.org | Web: www.seanav.org | 24/7 Emergency: +971 50 123 4567