200+
PMS / load sharing refits
MAN, Wärtsilä
OEM trained on major makes
24/7
emergency response
Experienced
team – 15+ years

⚡ power management systems (pms)

Load Sharing · Gen Protection · Blackout Recovery

  • Load shedding & prioritizationtrip non-essential consumers
  • Generator protectionoverload, reverse power, under freq
  • Blackout preventionspinning reserve, load dependent start
  • Fast load reductionfor shaft generator/PTO modes
  • Instant blackout recoveryauto start/ sync of standbys
  • PMS integrationwith propulsion control, thrusters
  • Frequency/load controlisochronous, droop
  • High-speed bus transferfor vital consumers
  • Shaft generator/GENOPTO management
  • Emergency generator auto start/stop
  • Load sharing (active/reactive)digital/analog
  • Integration with IAS/AMS/ECS

Experienced with ABC, Daihatsu, Bergen, Yanmar, Caterpillar, MAK, Niigata – our team delivers.

🔋 power management systems (pms)

PMS · Load Sharing · Generator Control

PMS makes & integrations

  • Kongsberg – K-PMS, K-Chief
  • Norcontrol – DataChief, AutoChief PMS
  • Lyngsø – X-Mod, X-PMS
  • Siemens – Siship, S7-400 based PMS
  • ABB – ECS, PMS 800, Marine & Ports
  • Wärtsilä – Nacos, UNIC PMS
  • Valmet – DAMATIC, DNA PMS
  • MAN CEON – cloud PMS modules
  • Mitsubishi – integrated automation
  • Rockwell / Allen Bradley – PLC based

Generator & Load control

  • Woodward – EasyGen, LSSC, GCP
  • DEIF – AGC, PPU, multi-liner controllers
  • ComAp – InteliGen, InteliMains marine
  • Deep Sea Electronics – DSE8xxx marine
  • Basler – DGC, DECS load sharing
  • GAC – LSM, LSC, digital load sharing
  • SEL (Schweitzer) – protection relays
  • Siemens Siprotec – generator protection

⚡ load shedding & blackout prevention

Fast load reduction · priority trip · recovery

Load shedding strategies

  • Real-time power monitoring – generator kW/ kvar
  • Load dependent start/stop – based on spinning reserve
  • Shedding priority tables – non-essential, semi-essential, essential
  • Fast load reduction (FLR) – for shaft generator/PTO trip
  • Under-frequency load shedding (UFLS)
  • kW and kvar based shedding
  • Manual / semi-auto override
  • Integration with propulsion drives – reduce thrust/pitch

Blackout prevention & recovery

  • Spinning reserve management – % margin
  • Auto start standby generatorbefore overload trip
  • Closed bus transfer / open bus – seamless switching
  • Blackout detection – <100V, <45Hz
  • Instant auto synchronizing – dead bus closure
  • Emergency generator auto connect
  • High-speed bus transfer (HSBT) for vital consumers
  • Post-blackout load ramp – avoid second blackout

🔧 generator & prime mover

Diesel / gas / shaft generators

  • MAN B&W – 23/30, 28/32, 32/40, 48/60 (genset control, load sharing)
  • Wärtsilä – 20, 26, 32, 46F (PMS integration, load shedding)
  • Caterpillar – 3500, 3600 series, C32, C280 (ADEM, electronic governors)
  • MAK – M20, M25, M32, M43 (genset automation)
  • Rolls-Royce Bergen – B32:40, C26:33 (load sharing & blackout prevention)
  • Niigata – 6L, 8L, 12L series gensets
  • Yanmar – 6EY, 8EY, 12EY (aux & emergency gensets)
  • ABC – DZ, VDZ genset engines (PMS retrofits)
  • Daihatsu – DK, DC series (aux genset control)
  • SEMT Pielstick – PA, PC series gensets
  • Shaft generators – PTO/PTI, frequency converters (Siemens, ABB, VACON)
  • Emergency generators – MTU, Scania, Volvo Penta (auto start / blackout recovery)

⚙️ propulsion & thruster integration

Load sharing with CPP, thrusters, shaft gen

Propulsion load control

  • CPP pitch reduction – on overload / shaft gen trip
  • Main engine power limit – via ShaPoLi / EPL
  • Thruster power limiting – Brunvoll, Schottel, Ulstein
  • DP system load feed – to PMS for total power
  • Azimuth / Z-drive load reduction
  • Integration with MAN Alpha / Wärtsilä Lips CPP
  • Combinator curve adaptation during load shed

Shaft generator / PTO cases

  • PTO trip fast load reduction – reduce propulsion instantly
  • Genopto / Shaft gen control – frequency/voltage support
  • Blackout recovery with shaft gen – re-sync
  • Load sharing between shaft gen & diesel gens
  • Integrated with frequency converters (VACON, ABB, Siemens)
  • Closed bus transfer PTO/PTH modes

🛡️ generator protection & relays

Reverse power · overcurrent · under voltage

Protection relays – makes

  • Siemens – Siprotec 5, 7UM, 7SR
  • ABB – REF, REM, REG 670
  • Schweitzer (SEL) – SEL-700G, 710, 751
  • GE Multilin – G60, 750, 850
  • DEIF – PPM, 587, multi-line
  • Basler – BE1-11, DGC-2020
  • Woodward – LSSC, easygen relay functions
  • ComAp – InteliGen relays

Protection functions

  • ✓ Reverse power / minimum power
  • ✓ Overcurrent (instantaneous, IDMT)
  • ✓ Under/over voltage & frequency
  • ✓ Loss of excitation / field failure
  • ✓ Negative phase sequence
  • ✓ Stator earth fault / rotor earth fault
  • ✓ Overload / load shedding trigger
  • ✓ Differential protection (87G)

🔧 retrofit & troubleshooting

Modernization · Legacy PMS · Diagnostics

  • Legacy PMS modernization – replacing obsolete load sharing modules
  • PLC-based load shedding – Siemens, Rockwell, Mitsubishi, B&R
  • HMI upgrade for power management – touchscreen, trending
  • Blackout prevention retrofit – fast load reduction / auto synchronizers
  • Load sharing card replacement – Woodward, GAC, Basler
  • Generator protection upgrade – numerical relays, communication
  • Frequency converter integration – for shaft gen/PTO stability
  • PMS troubleshooting – on-site diagnostic, software validation
  • Network integration – Modbus, Profibus, CANopen, Ethernet/IP
  • Spare parts supply – for all PMS / load shedding makes

🌍 service coverage

Vessels We Protect from Blackout

Vessel Types

  • ✓ Tankers (VLCC, Aframax, Product)
  • ✓ Bulk Carriers (Capesize, Panamax)
  • ✓ Container Vessels (Post-Panamax)
  • ✓ LNG / LPG Carriers
  • ✓ Offshore Vessels (PSV, AHTS, OSCV)
  • ✓ Drilling Rigs (Jack-up, Semi-sub)
  • ✓ FPSO / FLNG / FSRU
  • ✓ Ro-Ro / PCTC / Car Carriers
  • ✓ Cruise Ships / Ferries
  • ✓ Naval Vessels

Global Service Locations

  • ✓ UAE – Dubai, Abu Dhabi, Fujairah
  • ✓ India – Mumbai, Kochi, Chennai, Kandla
  • ✓ Singapore – Jurong, Tuas
  • ✓ Middle East – Qatar, Saudi, Kuwait
  • ✓ Europe – Rotterdam, Hamburg, Piraeus
  • ✓ Asia – South Korea, China, Japan
  • ✓ Worldwide – all major ports and shipyards

⚡ 24/7 blackout prevention support

Need Load Shedding or Blackout
Prevention retrofit?

Our power management engineers provide complete installation, troubleshooting, retrofit, and repair for all load shedding & blackout prevention systems – PMS, generator protection, load sharing, frequency control, blackout recovery. Available 24/7 worldwide.

Email: service@seanav.org | Website: www.seanav.org