Description
System Overview & Engineering Architecture
The Electronic Chart Display and Information System HLD-ECDIS 600 represents Highlander’s independently developed solution for modern maritime navigation. Engineered for “paperless navigation,” this system integrates advanced electronic chart capabilities with real-time sensor data processing. The architecture comprises a Main Control Unit (HLD-MCU770), Display Units, and Interactive Units, all interconnected via LAN for seamless data exchange. The system software has been validated through actual shipboard deployment, ensuring operational reliability and user-friendly interface design.
Core Features & Operational Advantages
- Chinese/English Switch: Provides bilingual interface support with an intuitive Chinese interface for enhanced operator usability.
- Track Control: Integrates with Highlander’s Steering Control System for automated rudder management, reducing manual intervention.
- ENC Update Online: Supports both local and remote chart data updates via LAN connectivity to database servers.
- Weather Routing: Displays wind, wave, and current data for route optimization based on shortest time, distance, or energy consumption criteria.
- NAVTEX Management: Receives and displays NAVTEX messages with positional plotting for restricted areas and hazards.
- Radar Image Overlay: Direct LAN integration with Highlander Radar; supports third-party radar via Extractor PCI boards.
- Comprehensive Training System: Offers STCW-compliant training at Highlander facilities, shipowner centers, or online platforms.
- Chart Data Display: Supports IHO S-57/S-63 formats with Mercator and Polar Stereographic projections for high-latitude navigation.
- IMO MSC.232(82):2006: Compliant with International Maritime Organization performance standards for ECDIS.
- IEC 61174:2015: Adheres to IEC specifications for electronic chart display and information systems.
- China Classification Society (CCS): Type-approved for use on Chinese-flagged vessels.
- DNV-GL EC MED (B+D): Holds EU Marine Equipment Directive certification for European markets.
- IEC 60945: Environmental and electromagnetic compatibility compliance for marine equipment.
- Visual inspection of display units and mounting hardware
- Verification of UPS battery health and backup duration
- ENC data integrity checks during scheduled updates
- Interface connectivity testing with ship sensors and VDR systems
- Software version verification against latest chart databases
Component Breakdown & Technical Specifications
The HLD-ECDIS 600 system consists of modular components designed for flexible installation:
| Component | Model |
|---|---|
| Main Control Unit | HLD-MCU770 |
| Display Unit (24") | HLD-DU 134 |
| Interactive Unit | HLD-IU 600 |
| Certificate ECDIS 600 (M) | Certificate ECDIS 600 (M) |
| Power Supply Unit | HLD-PCU 600 |
System Technical Parameters
| Parameter | Specification |
|---|---|
| Product Standards | IMO MSC.232(82):2006, IEC 61174:2015 |
| Display Unit | 3 models available, 19" to 27" |
| Operating System | Windows 7 (EN) |
| Interface Input | Serial or LAN – Own ship sensor data / ENC / PERMIT / CERTIFICATE / Charts UPDATE / External alerts |
| Interface Output | Serial or LAN – VDR / INS interface / TCS interface / BAMs |
| Power Supply | 115–230 VAC and 24 VDC input, 300 W |
| UPS | 115–230 VAC input, 1 kVA |
| Working Environment | IEC 60945 standards |
| Temperature Range | -15 °C to +55 °C |
Process Unit Specifications
| Parameter | Specification |
|---|---|
| Processor | Intel® Core™ |
| Internal Storage | DDR3, 8 GB |
| Storage | SSD 250 GB |
| Size (L × W × H) | HLD-MCU770: 293 × 194 × 160 mm |
| Operating Temperature | -15–55 °C |
| Storage Temperature | -20–60 °C |
| Power Input | 18–36 VDC input |
Physical & Environmental Parameters
| Parameter | Specification |
|---|---|
| Installation | Desk mount / Embedded mount |
| Weight (about) | 2.5 kg |
| EMC/EMI | IEC 60945 |
SOLAS, IMO, IEC & Classification Society Compliance
The HLD-ECDIS 600 meets stringent international maritime standards:
For vessels operating in UAE waters and internationally, the HLD-ECDIS 600 supports compliance with SOLAS Chapter V navigation requirements and is suitable for integration with VDR/S-VDR systems for complete voyage data recording.
Onboard Maintenance & Inspection Standards
The HLD-ECDIS 600 is designed for minimal maintenance with solid-state components and industrial-grade construction. Regular inspection protocols include:
Scheduled maintenance aligns with ECDIS annual inspection standards and manufacturer-recommended service intervals. Authorized technicians can perform firmware updates and system diagnostics through secure remote access protocols.
Technical Support & Port Delivery
Seanav Marine provides comprehensive technical support for the HLD-ECDIS 600 across major UAE ports including Jebel Ali, Port Rashid, Khalifa Port, and Port of Fujairah. Our certified engineers offer installation, commissioning, and ongoing maintenance services. We maintain an inventory of critical spare parts including display units, power supply modules, and interface cables. For emergency support or scheduled service appointments, contact our technical team at Contact Seanav Marine Technical Team.
Related services include marine gyrocompass maintenance and GMDSS radio survey preparation for integrated bridge system compliance.
Frequently Asked Questions
What are the main components of the HLD-ECDIS 600 system?
The system consists of the Main Control Unit (HLD-MCU770), Display Units (HLD-DU series), Interactive Unit (HLD-IU 600), Power Supply Unit (HLD-PCU 600), and optional accessories including mounting brackets and interface adapters.
Is the HLD-ECDIS 600 compliant with IMO and IEC standards?
Yes, the system meets IMO MSC.232(82):2006 and IEC 61174:2015 standards, with type approval from China Classification Society (CCS) and EU (EC) MED (B+D) certification by DNV-GL.
Can the HLD-ECDIS 600 support dual workstation configuration?
Yes, the system can be configured as a dual workstation setup and can also be integrated into an Integrated Navigation System (INS).
What chart formats does the HLD-ECDIS 600 support?
The system supports IHO S-57 and S-63 electronic chart formats with Mercator Projection and Polar Stereographic Projection for high-latitude navigation.
How does weather routing function work on the HLD-ECDIS 600?
The system loads and displays weather data including wind, waves, and ocean currents. It generates routes based on departure and destination ports, with optimization options for shortest time, shortest distance, or lowest energy consumption.
What training options are available for HLD-ECDIS 600 operators?
Training is available at Highlander offices, authorized engineering agencies, shipowner training centers, or through Highlander’s online education system, meeting STCW convention requirements.
Can the HLD-ECDIS 600 overlay radar images?
Yes, Highlander Radar integrates directly via LAN. For third-party radar systems, an Extractor Radar Acquisition PCI Board adapter is required for echo overlay.
What is the power supply requirement for the HLD-ECDIS 600?
The system supports 115–230 VAC and 24 VDC input at 300 W, with a UPS providing 115–230 VAC input at 1 kVA capacity.
What are the operating temperature ranges for the HLD-ECDIS 600?
The system operates within -15 °C to +55 °C, with storage temperature range of -20–60 °C, complying with IEC 60945 environmental standards.
Where can I get technical support for HLD-ECDIS 600 in the UAE?
Seanav Marine provides 24/7 technical support across UAE ports including Jebel Ali, Port Rashid, Khalifa Port, and Port of Fujairah. Contact our technical team at https://seanav.org/contact.
Manufacturer documentation and compatibility
Select the exact model, hardware generation and document revision. Before ordering, confirm the equipment interfaces, power requirements, required approvals and included accessories against the applicable manufacturer documentation. Send nameplate photographs, the installed equipment details, vessel name, port and ETA with your enquiry.